These changes fix logical consistency and correctness issues with the instruction definitions as printed in the SH4 manual. The most serious issues were: - div0u/div0s/div1 use `m` as a temporary variable which contradicts the existence of the `m` register number - missing semicolons - inconsistent references to immediate and displacement variable names
5 lines
76 B
Plaintext
5 lines
76 B
Plaintext
1110nnnniiiiiiii
|
|
imm ← SignExtend8(i);
|
|
op2 ← imm;
|
|
Rn ← Register(op2);
|