Field Name Bits Default Description
|
|
PVS_FC_OPC_0 1:0 0x0 This opcode field determines what type of control flow
|
|
instruction to execute.
|
|
0 = NO_OP
|
|
1 = JUMP
|
|
2 = LOOP
|
|
3 = JSR (Jump to Subroutine)
|
|
PVS_FC_OPC_1 3:2 0x0 See PVS_FC_OPC_0.
|
|
PVS_FC_OPC_2 5:4 0x0 See PVS_FC_OPC_0.
|
|
PVS_FC_OPC_3 7:6 0x0 See PVS_FC_OPC_0.
|
|
PVS_FC_OPC_4 9:8 0x0 See PVS_FC_OPC_0.
|
|
PVS_FC_OPC_5 11:10 0x0 See PVS_FC_OPC_0.
|
|
PVS_FC_OPC_6 13:12 0x0 See PVS_FC_OPC_0.
|
|
PVS_FC_OPC_7 15:14 0x0 See PVS_FC_OPC_0.
|
|
PVS_FC_OPC_8 17:16 0x0 See PVS_FC_OPC_0.
|
|
PVS_FC_OPC_9 19:18 0x0 See PVS_FC_OPC_0.
|
|
PVS_FC_OPC_10 21:20 0x0 See PVS_FC_OPC_0.
|
|
PVS_FC_OPC_11 23:22 0x0 See PVS_FC_OPC_0.
|
|
PVS_FC_OPC_12 25:24 0x0 See PVS_FC_OPC_0.
|
|
PVS_FC_OPC_13 27:26 0x0 See PVS_FC_OPC_0.
|
|
PVS_FC_OPC_14 29:28 0x0 See PVS_FC_OPC_0.
|
|
PVS_FC_OPC_15 31:30 0x0 See PVS_FC_OPC_0.
|