Field Name Bits Default Description
PIPE0_ID 1:0 0x0 Maps physical pipe 0 to logical pipe ID (def 0).
PIPE1_ID 3:2 0x1 Maps physical pipe 1 to logical pipe ID (def 1).
PIPE2_ID 5:4 0x2 Maps physical pipe 2 to logical pipe ID (def 2).
PIPE3_ID 7:6 0x3 Maps physical pipe 3 to logical pipe ID (def 3).
PIPE_MASK 11:8 0x0 4b mask, indicates which physical pipes are enabled (def
none=0x0) -- B3=P3, B2=P2, B1=P1, B0=P0. -- 1:
enabled, 0: disabled
MAX_PIPE 13:12 0x3 2b, indicates, by the fuses, the max number of allowed
pipes. 0 = 1 pipe ... 3 = 4 pipes -- Read Only
BAD_PIPES 17:14 0xF 4b, indicates, by the fuses, the bad pipes: B3=P3, B2=P2,
B1=P1, B0=P0 -- 1: bad, 0: good -- Read Only
CONFIG_PIPES 18 0x0 If this bit is set when writing this register, the logical
pipe ID values are assigned automatically based on the
values that are read back in the MAX_PIPE and
BAD_PIPES fields. This field is always read back as 0.
POSSIBLE VALUES:
00 - Do nothing
01 - Force self-configuration