KAEDE/Mpglobal.h KAEDE/MPDRV_.C KAEDE/MPAPI_.C MAPLE82E.pdf Chapter 6 "COMMAND REFERENCE" jargon: AP - Absolute Position ; MAPLE82E.pdf page 13 / page 21 (Address) (Data) 0x0C700000 → 0x00000000 Port 0, 4-byte data transmission (instruction to Maple-Host) 0x0C700004 → 0x0C800000 Port 0, reception data storage address (instruction to Maple-Host) 0x0C700008 → 0x01200000 [Device Request], transfer destination AP: 0x20, transfer source AP: 0x00 0x0C70000C → 0x00010000 Port 1, 4-byte data transmission 0x0C700010 → 0x0C800100 Port 1, reception data storage address 0x0C700014 → 0x01604000 [Device Request], transfer destination AP: 0x60, transfer source AP: 0x40 0x0C700018 → 0x00020000 Port 2, 4-byte data transmission 0x0C70001C → 0x0C800200 Port 2, reception data storage address 0x0C700020 → 0x01A08000 [Device Request], transfer destination AP: 0xA0, transfer source AP: 0x80 0x0C700024 → 0x80030000 Port 3, 4-byte data transmission 0x0C700028 → 0x0C800300 Port 3, reception data storage address 0x0C70002C → 0x01E0C000 [Device Request], transfer destination AP: 0xE0, transfer source AP: 0xC0 --- (Specified reception data storage address: 0x0C800000) 0x0C800000 → 0x0500201C [Device Status], transfer destination AP:00, transfer source AP:20 0x0C800004 → 0x00000001 112 bytes of fixed data follows � � 0x0C800070 → 0x00000000 0x0C800000 → 0xFFFFFFFF No connection 0x0C800000 → 0xFFFFFF00 Reception data error ---- (Address) (Data) 0x0C700000 → 0x00000001 Port 0, 8-byte data transmission (instruction to Maple-Host) 0x0C700004 → 0x0C800000 Port 0, reception data storage address (instruction to Maple-Host) 0x0C700008 → 0x09200001 [Get Condition], transfer destination AP: 0x20, transfer source AP: 0x00 0x0C70000C → 0x00000001 Function type 0x0C700010 → 0x00010001 Port 2, 8-byte data transmission 0x0C700014 → 0x0C800100 Port1, reception data storage address 0x0C700018 → 0x09604001 [Get Condition], transfer destination AP:0x60, transfer source AP:0x40 0x0C70001C → 0x00000001 Function Type 0x0C700020 → 0x00020001 Port 2, 8-byte data transmission 0x0C700024 → 0x0C800200 Port 2, reception data storage address 0x0C700028 → 0x09A08001 [Get Condition], transfer destination AP: 0x80, transfer source AP: 0xA0 0x0C70002C → 0x00000001 Function type 0x0C700030 → 0x80030001 command list end Port 3, 8-byte data transmission, 0x0C700034 → 0x0C800300 Port 3, reception data storage address 0x0C700038 → 0x09E0C001 [Get Condition], transfer destination AP: 0xC0, transfer source AP: 0xE0 0x0C70003C → 0x00000001 Function Type --- SB_MDSTAR 0x005F6C04: Starting address setting for the command table in system memory Settable area: 0x0C000000 - 0x0FFFFFE0 SB_MDTSEL 0x005F6C10: Maple-DMA trigger setting 0x00000000 : Software trigger 0x00000001 : Hardware trigger SB_MDEN 0x005F6C14: Enables Maple-DMA (Read) 0x00000000 : Disable 0x00000001 : Enable (Write) 0x00000000 : Disable 0x00000001 : Enable SB_MDST 0x005F6C18: Maple-DMA software start (Read) 0x00000000 : Maple-DMA end 0x00000001 : Maple-DMA transfer in progress (Write) 0x00000000 : Invalid 0x00000001 : Maple-DMA start SB_MSYS 0x005F6C80: Maple system control setting For details, refer to section 8.4.1.1, "System Registers." SB_MDAPRO 0x005F6C8C: Maple-DMA area protection setting Settable area: 0x0C000000 to 0x0FFFFFE0 SB_ISTNRM 0x005F6900: Normal interrupt status bit12: Maple-DMA end For details on interrupt registers, refer to section 8.4.1.1, "System Registers."